Evaluation the effect of exchange time anesthetic circuit anti- bacterial filters, on microbial culture results of anesthetic circuits in Bouali Hospital operating theaters
Farshid Gholami *1, Mahnaz Narimani Zaman Abadi 2, Seyed Ahmad Seyed Mehdi 2, Mohammad Aryafar 2, Ladan Ansari 2, Majid Shakiba 3
1- Assistant Professor Bu-Ali Hospital, Department of Anesthesiology , frgholami@gmail.com
2- Assistant Professor Bu-Ali Hospital, Department of Anesthesiology
3- Physician Bu-Ali Hospital
Abstract:   (592 Views)
Background: To prevent the anesthesia circuit from bacterial colonization, during the time, we used to have an antibacterial filters with no predicted changing algorithm. In this study, we evaluated the effect of exchange time anesthetic circuit anti- bacterial filters, on microbial culture results of anesthetic circuits in Bouali Hospital operating theaters. Materials and methods: During a descriptive-analytic study, we changed the antibacterial filters in 4 different operating rooms; per patients at 1st room, daily at 2d room, 2times a week at 3rd room & weekly at the last one and kept them for the first week of study. At the rest of time until 10 months, we changed the filters in a manner to equal changing algorithm on all 4 rooms. we had microbial culture exam from the Y-piece & Mount-catheter every week ends. Results: Changing filter algorithm were 243 surgeries (25.5%) per patient (group1), 243 surgeries (25.5%) daily (group2), 237 surgeries (24.6%) twice a week (group3) and 241 surgeries (25%) weekly (group 4). The positive culture results were obtained on 21 operations (2.2%) in Y-piece and 27 operations (2.8%) in Mount-catheter. Conclusion: When we consider the whole number of surgeries in one day as a unit, positive culture results on Y-piece in each group would be 1(2.6%) for group1, 0 for group 2 , 2 (5%) for group 3, 1(2.5%) for group 4 (P=0.9). For Mount-catheter positive culture results were 2(5.1%) for group 1, 0 for group 2, 1(2.5%) for group 3 and 1(2.5%) for group 4 (P=0.6). No differences were found on concomitant positive culture tests from Y and Mount pieces. Keywords: Microbial culture, Anesthesia circuit, Anti-bacterial filter.
Keywords: Microbial culture, Anesthesia circuit, Anti-bacterial filter
Full-Text [PDF 176 kb]   (135 Downloads)    
Type of Study: Survey/Cross Sectional/Descriptive | Subject: Anesthesiology
Received: 2016/08/31 | Accepted: 2017/04/30 | Published: 2017/09/23
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Gholami F, Narimani Zaman Abadi M, Seyed Mehdi S A, Aryafar M, Ansari L, Shakiba M. Evaluation the effect of exchange time anesthetic circuit anti- bacterial filters, on microbial culture results of anesthetic circuits in Bouali Hospital operating theaters. MEDICAL SCIENCES. 2017; 27 (3) :209-212
URL: http://iau-tmuj.ir/article-1-1300-en.html


Volume 27, Issue 3 (fall 2017) Back to browse issues page
فصلنامه علوم پزشکی دانشگاه آزاد اسلامی واحد پزشکی تهران Medical Science Journal of Islamic Azad Univesity - Tehran Medical Branch
Persian site map - English site map - Created in 0.051 seconds with 810 queries by yektaweb 3600