[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Webmail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Volume 25, Issue 1 (Spring 2015) ::
MEDICAL SCIENCES 2015, 25(1): 55-58 Back to browse issues page
Comparing radiation receiving dose at 50 Cm distance of the source of radiation and nearby room during fluoroscopic percutaneous nephrolithotomy
Mahboubeh Safavi1 , Seyed Mohammad Masoud Shoushtarian2 , Mohammad Fesharaki3 , Majid Ansari 4
1- in Nursing Management, Faculty Member of Islamic Azad University, Tehran Medical Sciences Branch, Tehran, Iran
2- in Medical Physics, Faculty Member of Islamic Azad University, Tehran Medical Sciences Branch, Tehran, Iran
3- in Biostatistics, Faculty Member of Islamic Azad University, Tehran Medical Sciences Branch, Tehran, Iran
4- MSc on Nursing Education, Islamic Azad University, Tehran Medical Sciences Branch, Tehran, Iran , Majidansari75@yahoo.com
Abstract:   (6499 Views)
Background: One of the radioactive sources in operating room is fluoroscopy which is used in a variety of surgical operations. Because the operating room walls are not protected by lead, this study was done to measure the radiation receiving dose at nearby room during fluoroscopic percutaneous nephrolithotomy.
Materials and methods: After randomization, we measured x-ray in distance of 0.5 m, behind wall (3.50 m), and 30 meter (background dose) in 40 urological procedures in a simultaneous manner for a period of two months by using 12 thermoluminescent chips, and compared the results using independent T test.
 Results: The total fluoroscopy time was 66.90 minutes and the mean voltage used was 76.38 kV. Mean radiation dose for 40 procedures received at a distance of 0.5 meter was 0.426 ± 0.188 with minimum of 0.260 and maximum 0.689 mSv, while radiation dose received by a nearby room was zero. There was statistically significant difference between the amount of radiation received at distance of 0.5 meter and the adjoining room (P <0.05).
Conclusion: The amount of radiation received at 0.5 meter was high and safety guidelines should be considered. Furthermore, the dose of radiation received in a neighboring room like the background dose was zero which means that working in adjoining rooms is safe.
Keywords: Radiation dose, Fluoroscopy, Percutaneous nephrolithotomy, Radiation
Full-Text [PDF 262 kb]   (4600 Downloads)    
Semi-pilot: Survey/Cross Sectional/Descriptive | Subject: Medical Physics
Received: 2015/03/9 | Accepted: 2015/03/9 | Published: 2015/03/9
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Safavi M, Shoushtarian S M M, Fesharaki M, Ansari M. Comparing radiation receiving dose at 50 Cm distance of the source of radiation and nearby room during fluoroscopic percutaneous nephrolithotomy. MEDICAL SCIENCES 2015; 25 (1) :55-58
URL: http://tmuj.iautmu.ac.ir/article-1-906-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 25, Issue 1 (Spring 2015) Back to browse issues page
فصلنامه علوم پزشکی دانشگاه آزاد اسلامی واحد پزشکی تهران Medical Science Journal of Islamic Azad Univesity - Tehran Medical Branch
Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4645